SMU Measures

SMU, or “Standard Meter Unit” measures are measures that represent the last known cumulative reading, rather than an instantaneous quantity. SMUs are almost always associated with physical metres, such as odometers or hour meters on equipment units, or total flow meters on pumps.

The key characteristic of SMU measures are that they should never decrease unless a calibration is performed. Any part of the Micromine Pitram application that allows recording of SMU readings should always confirm that the number entered is greater than, or equal to, the previous entry.

Calibration

Periodically SMU measures need to be calibrated. This could be due to the physical meter being replaced or simply due to the fact that entered readings have become different to the physical meter that they represent.

Whenever a calibration is entered, all preceding readings for that measure are ignored. The calibration acts as a known reading.

A calibration requires two values, a current reading and an absolute reading. The current reading represents the number currently on the meter, while the absolute reading determines the total accumulated value for the lifetime of the equipment. These numbers will often be the same. 

The prime example of when they may be different is if an hours meter is replaced on an equipment unit. A new meter will probably read 000000, but we know that the equipment has worked 20000 hours in its lifetime.  In this example, Micromine Pitram would record 0 as the current reading and 20000 as its absolute reading. From this point on Micromine Pitram will add the difference between the absolute and current readings (20000 – 0) to all entered readings to provide the total hours worked for the equipment.

Hours Validation

The majority, but not all, SMU measures will be related to hours. For these measures, Micromine Pitram can provide additional validation when the user enters a measure. Micromine Pitram can also check the difference between the entered reading and the last reading, and check ensure this difference is not greater than the calendar time between the readings.

For example, if the equipments engine hours reading was 250 at 8am and the user attempts to enter a reading of 260 at 12 noon the same day, Micromine Pitram informs the user that this is not possible as only 4 hours have elapsed – how is it possible that the equipment unit has worked 10 hours in this time.

This validation will be applied to an SMU measure if the MEASURE reference group has an attribute of ValidateAgainstCalendarHours and the value of this attribute is 1.