The following table contains troubleshooting information on any issues that may occur with Mobile on the tablet, or the drill data in DOME.
| What you see | Why | What to do |
|---|---|---|
| Tablet | ||
| "No Drill Data profile configured" | The rig's unit configuration has no Drill Data Profile. | Administrator sets DrillDataProfile on the rig's MobileUnitConfiguration and publishes reference data. |
| "No drill plan for this location" | The ring the rig is allocated to has no published plan, or the plan has no Plan ID. | Check the allocation is the right ring. In DOME check the plan is Published, not Unpublished, On hold or Complete. Wait for the tablet to synchronise. |
| Submit stays disabled | No actual length entered, no measure selected, or the status is still Not started. | Enter the length, pick a measure, set the status. |
| A parameter from the plan is missing | The profile's parameter list does not include it, or its planned flag is off. | Administrator adds the parameter to the profile's active list. |
| Holes drilled last shift show as not started | The plan was replaced with a new Plan ID, or the retention period has passed, or the holes were submitted from a different tablet. | Old actuals are still in reporting. Raise EventRetentionDays if rings outlive 62 days. Keep one tablet per rig where possible. |
| DOME | ||
| Import rejects a ring as published or complete | Rings on a published or complete plan cannot be changed by import. | Unpublish (or Reopen) the plan, import, then publish again. |
| Import rejects rows for a missing location or ring | The file's location or ring does not match PITRAM, or the code/description switch is wrong. | Fix the names in the file or tick the code/description option to match. For IREDES, map the positions to rings when asked. |
| Import rejects rows for a missing location or ring | The file's location or ring does not match PITRAM, or the code/description switch is wrong. | Fix the names in the file or tick the code/description option to match. For IREDES, map the positions to rings when asked. |
| Drill Plans screen is blocked | PITRAM reference data could not be read. | Wait for the reference data service and press Refresh. |
| Reporting | ||
| A hole shows no metres | Its length did not change in the period, or the Measure criterion does not match the measure the driller picked. | Widen the period or select the right measure code. |