EntryOfMeasureAgainstLocLR 

Automatic status change required: The charge up wagon has completed working on a face and calls in the face charged measure. The location status changes to: To Fire

Reference data group involved EntryOfMeasureAgainstLocLR - When a measure is entered against a location, the status of the location is changed.

Status Selection Mode: Automatic - Conditional Prompt

The active lists that you will be working with are:

Active List Members
Production Drill Locations UGLocA, UGLocB
PrimaryLocStates Charging, Firing, Drilling
SecondaryLocStates To Bolt, To Charge, To Fire

To define the EntryOfMeasureAgainstLocL automatic status change:

  1. Go to Groups | Configuration Items | States | Location Status Rules | EntryOfMeasureAgainstLocLR.
  2. Select Checkout on the header.
  3. Click New EntryOfMeasureAgainstLocLR.
  4. Enter the following definition:
Option Select
General
Code AFTERCHARGETOFIRE
Description After Charging: Status To Fire
Abbreviation After Charging: Status To Fire
Attribute
Locations*

Production Drill Locations

The location of the drill must be a member of this active list.

Parent location: If the measure is entered against a sublocation, the parent location of the set of sublocations to which the status change will apply, MUST be a member of the defined active list.

InitialLocStatusClassification*

Primary

One of the defined LocationStatusClassification. It references the active list defined in InitialLocStates.

InitialLocStates

PrimaryLocStates

Use if the location can be a member of a list of states.The location must be in one of the states listed in this active list: Blasting, Bogging, Drilling and others.

Not

InitialLocState Use if the location is in the defined state prior to to the rule being executed.
MeasureCode*

Face Charged

The measure that will be cumulated if the status remains the same for the current period and the status is a member of the PrimaryLocStates.

Duration

Defines the duration of the current status after which the status of the location will change.

Used only when MeasureCode = HOURS.

Applicable only if StatusSelectionMode = Automatic - No Prompt

Conditional %*

0

StatusSelectionMode is set to Automatic - Prompt (not Automatic - Conditional Prompt), so this value is not used.

Not applicable is Duration has been defined.

StatusSelectionMode*

Automatic - Prompt

Reference will be made to the value of the Planned Metres Drilled for the location.

ManualSelectionStates*

SecondaryLocStates

If the StatusSelectionMode is manual, any of the states in this active list can be selected. The location can be changed to: To Bolt, To Bog, To Fire or another listed, for example.

AutomaticSelectionStatus* To Fire
LocStatusClassification*

Secondary

One of the defined LocationStatusClassification. It references an active list of which To Fire is a member.

LocationTargetAttribute

Not required because the selection status change mode is not Conditional Prompt.

Not applicable if Duration has been defined.

* Required attributes

InitialLocStates (refers to an active list of states) and InitialLocationState refers to a single status) must be used if defined and the union of the InitialLocStates and InitialLocState is valid:

Duration attribute supports only StatusSelectionMode = Automatic - No Prompt.

  1. Click OK to save your settings.
  2. Click Checkin on the header.
  3. Click Publish on the navigation pane header.
  4. In the Publish dialog, click Publish. You will receive a message to say that publishing has been successful. Click OK to close the message.

Wait until the version number of the reference edit group (EntryOfMeasureAgainstLocLR) is updated to the latest version.

In Data Acquisition

You will be setting:

  • The location UGLocB to a Charging status.
  • The Chargeup wagon CH03 to work at UGLocB.
  • The Chargeup wagon CH03 to a primary status of Operating.
  1. Make sure that the status bar shows the latest version.
  2. In the Locations tab of the Data Groups pane, filter on Production Drill Equipment and select UGLocB.
  3. Right-click and select Set Location Status | Primary | Charging.
  4. In the Equipment tab of the Data Groups pane, filter on ChargeUp Equipment and select CH03.
  5. Set the following options for CH03:
    OptionSelect
    Allocate to Location UGLocB
    Set Primary StatusOperating
  6. For this status change rule, the measure is entered against the location. Go back to the Data Groups | Location pane.
  7. Right-click on UGLocB and select Enter Measure.
  8. Enter the following:
    OptionValue
    Face Charged1
  9. Click OK to save the measure. You will be prompted to change the location status.
  10. Click Yes to change the location status.
  11. Go to the Data Groups | Locations pane and select UGLocB.
  12. Right-click and select Set Location Status | Secondary. The status has been changed to To Fire.